TM5-6130-301-13&P
Table 2-2. OPERATOR/CREW PREVENTIVE MAINTENANCE CHECKS AND SERVICES
BBefore
AAfter
DDuring
QQuarterly
Procedures
Item
Item To Be
Equipment Is Not
Check for and have repaired or
No.
Inspected
ad,justed as necessary
Ready If
Case, three (3)
1
Battery charging
Visually inspect for broken or
each case latches
distribution panel case
damaged case, case latches or
or one or more
case handles.
case handles are
broken or damaged
Rheostats, meters,
Visually inspect distribution panel
2
Distribution panel
for damaged or broken rheostats,
or circuit breakers
are broke or damaged.
circuit breakers and circuit
breaker boots.
Rheostats, meters,
Inspect rheostats, meters,
switch and circuit
switches and circuit breakers
breakers do not
for proper operation.
operate.
Receptacles have
loose connections
connections.
Loose connections
Loosen fasteners and lift panel
are left untightened
to inspect wiring for loose
or cause of
connections or evidence of
overheating is not
overheating or cleanness of
corrected.
component.
Inspect ground lug for
panel is not
loose ground wire
properly grounded
connection.
More than half the
3
Cables
Visually inspect for bent broken
plugs or alligator
or missing plugs and alligator
clips are broken,
clips, damaged insulation, and
bent or missing.
corroded alligator clips.
Insulation is
damaged exposing
bare wire.
Insulation is damaged
Clean and inspect cables for
exposing bare wire.
damaged insulation and bent,
PlugS or alligator
broken or missing plugs or
clips are bent,
alligator clips.
broken or missing.
Change 1