TB 9-2320-280-35-11
35-51. Attach shrink tubing (109) and terminal lug (107) to EPLRS positive power terminal (124). Secure
to terminal board stud (92) with existing nut (108).
35-52. Attach shrink tubing (109) and terminal lug (107) to EPLRS negative power terminal (115). Secure
to terminal board stud (101) with existing nut (108).
35-53. Attach shrink tubing (109) and terminal lug (107) to lower SINCGARS positive power
terminal (123). Secure to terminal board stud (93) with existing nut (108).
35-54. Attach shrink tubing (109) and terminal lug (107) to lower SINCGARS negative power
terminal (114). Secure to terminal board stud (102) with existing nut (108).
35-55. Attach shrink tubing (109) and terminal lug (107) to front SINCGARS positive power
terminal (122). Secure to terminal board stud (94) with existing nut (108).
35-56. Attach shrink tubing (109) and terminal lug (107) to front SINCGARS negative power
terminal (113). Secure to terminal board stud (103) with existing nut (108).
35-57. Attach shrink tubing (109) and terminal lug (107) to PLGR positive power terminal (121). Secure to
terminal board stud (95) with existing nut (108).
35-58. Attach shrink tubing (109) and terminal lug (107) to PLGR negative power terminal (112). Secure
to terminal board stud (104) with existing nut (108).
35-59. Attach shrink tubing (109) and terminal lug (107) to white control cable positive terminal (119).
Secure to terminal board stud (97) with existing nut (108).
35-60. Attach shrink tubing (109) and terminal lug (107) to black control cable negative terminal (110).
Secure to terminal board stud (106) with existing nut (108).
35-61. Attach shrink tubing (109) and terminal lug (107) to upper SINCGARS positive power
terminal (118). Secure to terminal board stud (98) with existing nut (108).
35-62. Attach shrink tubing (109) and terminal lug (107) to upper SINCGARS negative power
terminal (116). Secure to terminal board stud (100) with existing nut (108).
35-63. Attach shrink tubing (109) and terminal lug (107) to
solenoid to
positive power terminal (120).
Secure to terminal board stud (96) with existing nut (108).
35-64. Attach shrink tubing (109) and terminal lug (107) to shunt to negative terminal (117). Secure to
terminal board stud (99) with existing nut (108).
35-65. Attach shrink tubing (109) and terminal lug (107) to
solenoid to
negative terminal (111). Secure to
terminal board stud (105) with existing nut (108).
99 100 101 102 103 104 105 106
97
98
95
96
94
92 93
107
108
109
110
124
116
115
121 120 119
111
122
114
112
118 117
113
123
109. SHRINK TUBING MS23053/4-302-0 QTY. A/R
Figure 5-128.
5-97