TB 9-2320-280-35-9
26-48. Attach shrink tubing (106) and terminal lug (104) to shunt negative terminal (124). Secure to
terminal board stud (125) with existing nut (105).
26-49. Attach shrink tubing (106) and terminal lug (104) to battery negative terminal (123). Secure to
terminal board stud (126) with existing nut (105).
26-50. Attach shrink tubing (106) and terminal lug (104) to left EPLRS negative power terminal (122).
Secure to terminal board stud (127) with existing nut (105).
26-51. Attach shrink tubing (106) and terminal lug (104) to SINCGARS negative power terminal (117).
Secure to terminal board stud (95) with existing nut (105).
26-52. Attach shrink tubing (106) and terminal lug (104) to right EPLRS negative power terminal (121).
Secure to terminal board stud (128) with existing nut (105).
26-53. Attach shrink tubing (106) and terminal lug (104) to NTDR power terminal (118). Secure to
terminal board stud (94) with existing nut (105).
26-54. Attach shrink tubing (106) and terminal lug (104) to third EPLRS negative power terminal (120)
and PLGR terminal (119). Secure to terminal board stud (129) with existing nut (105).
26-55. Attach shrink tubing (106) and terminal lug (104) to right EPLRS positive terminal (112). Secure to
terminal board stud (98) with existing nut (105).
26-56. Attach shrink tubing (106) and terminal lug (104) to SINCGARS positive terminal (116) and
NTDR positive terminal (115). Secure to terminal board stud (96) with existing nut (105).
26-57. Attach shrink tubing (106) and terminal lug (104) to left EPLRS positive terminal (111). Secure to
terminal board stud (99) with existing nut (105).
26-58. Attach shrink tubing (106) and terminal lug (104) to positive to battery cable (110) and PLGR
positive terminal (100). Secure to terminal board stud (98) with existing nut (105).
26-59. Attach shrink tubing (106) and terminal lug (104) to right EPLRS positive power terminal (112).
Secure to terminal board stud (98) with existing nut (105).
26-60. Attach shrink tubing (106) and terminal lug (104) to charge control box blue (109) and yellow (108)
terminals. Secure to terminal board stud (101) with existing nut (105).
26-61. Attach shrink tubing (106) and terminal lug (104) to charge control box red wire terminal (107).
Secure to terminal board stud (102) with existing nut (105).
26-62. Attach shrink tubing (106) and terminal lug (104) to digital duo-charge power cable terminal (106).
Secure to terminal board stud (103) with existing nut (105).
26-63. Attach shrink tubing (106) and terminal lug (104) to third EPLRS positive terminal (113) and
PLGR positive terminal (114). Secure to terminal board stud (97) with existing nut (105).
96 97
94 95
128 129
126 127
125
98 99 100 101 102
103
124
104
123
105
122
106
121
120
107
119 118
117
116
115
114 113
112 111 110 109 108
106. SHRINK TUBING MS23053/4-302-0 QTY. A/R
Figure 5-94.
5-84