TESTING - Continued
5.
If a Load Tester is not available an alternate method of testing the battery is approved: Using a battery analyzer
meter such as 490PT (available in SATS) measure the battery voltage and CCA rating. Note this meter reading
is not a true CCA value; however it is considered a reliable reflection of the batteries capacity. For a used
battery if the CCA value indicated on the meter is less than the batteries CCA rate additional charging is
required or disposal is recommended.
6.
Disposal: Battery determined by the above tests to be disposed of should be marked as "BAD-TESTED" and
date of test.
END OF TASK
END OF WORK PACKAGE