TM 11-6140-203-14-3
Current at rated load (14 am-Temperatures between 700
pere):
F. (21.10 C.) and 850 F.
(29.40 C.) ..................12 volts for approximately 5
Temperatures between
hours.
0F. (-17.8C.) and
Temperatures between 0F.
125F. (51.7C.)
14 ampere for approximately 5
(-17.8C.) and -40F.
hours.
(-40C.) ....................11.5 volts for approximately 3
hours.
Temperatures between
Intercell connector (molded in
0F. (-17.80 C.) and
place):
-40'F (-40C)
14 ampere for approximately 3
Material .....................Nickel-Plated copper.
hours.
Number .....................9.
Voltage:
Cell plate materials:
Open circuit .............. Approximately 13 volts (fully
Positive (charged)......Nickel oxide.
charged, with a 24-hour rest
Negative (charged) ....Cadmium.
period).
Separator material ....Nylon cellophane sandwich.
Under rated load (14 ampere):
2-14