TB 9-2320-280-35-12
47-38. Attach shrink tubing (35) and terminal lug (67) to PLGR power cable (69) and red wire (68) from
battery alarm box cable. Secure cable (69) and wire (68) to terminal board hole (70) in terminal
board (32) with existing screw (34).
47-39. Attach shrink tubing (35) and terminal lug (67) to blue wire (71) from battery alarm box cable and
yellow wire (73) from battery alarm box cable. Secure wires (71) and (78) to terminal board hole (72)
with existing screw (34).
47-40. Attach shrink tubing (35) and terminal lug (67) to DC-DC adapter power cable (75). Secure cable
(75) to terminal board hole (74) with existing screw (34).
47-41. Attach shrink tubing (35) and terminal lug (67) to PLGR negative cable (76) and DC-DC adapter
negative cable (77). Secure cables (76) and (77) to terminal board hole (78) with existing screw (34).
47-42. Attach shrink tubing (35) and terminal lug (67) to black wire (80) from battery alarm box cable and
master kill switch box negative cable (81). Secure wire (80) and cable (81) to terminal board hole
(79) with existing screw (34).
32
67
34
70
35
69
68
73
72
71
74 75
76 77 78 79 80 81
67. TERMINAL LUG CRS-DY-1810 QTY. 9
Figure 5-145.
5-105