TB 9-2320-280-35-12
47-43. Attach shrink tubing (35) and terminal lug (83) to orange wire (82) from battery alarm box cable.
Secure wire (82) to shunt (47) with existing screw (84).
47-44. Attach shrink tubing (35) and terminal lug (83) to green wire (88) from battery alarm box cable.
Secure wire (85) to shunt (47) with existing screw (84).
47-45. Attach shrink tubing (35) and terminal lug (83) to DC charger negative output cables (86) and (87).
Secure cables (86) and (87) to shunt (47) with existing screw (45).
47-46. Attach shrink tubing (35) and terminal lug (83) to DC charger positive output cables (89) and (90).
Secure cables (89) and (90) to negative terminal (96) on battery (95).
47-47. Attach shrink tubing (35) and terminal lug (83) to DC charger negative output cables (91) and (93).
Secure cables (91) and (93) to negative terminal (96) on battery (95).
47-48. Attach shrink tubing (35) and terminal lug (83) to DC charger positive output cables (92) and (94).
Secure cables (92) and (94) to positive terminal (97) on battery (95).
85
84
83
82
47
45
94
93
88
92
84
91
90
87
89 86
87
86
83
95
35
96
97
83. TERMINAL LUG CRS-DY-1410 QTY. 10
Figure 5-146.
5-106