TM 11-6140-203-14-4&P
SECTION III. TOOL AND TEST EQUIPMENT REQUIREMENTS
FOR
NICKEL-CADMIUM BATTERY BB-693A/U
(1)
(2)
(3)
(4)
(5)
TOOL OR TEST
EQUIPMENT
MAINTENANCE
NATIONAL/NATO
TOOL
REF CODE
LEVEL
NOMENCLATURE
STOCK NUMBER
NUMBER
1
F, H, D
FIXTURE, BATTERY DISCHARGE AND CELL -
6110-00-014-6225
VOLTAGE BALANCING MX-8927A/U FOR
BB-693A/U BATTERY
2
O, F, H, D
MULTIMETER TS-352B/U (NOTE 6)
3
F, H, D
TOOL KIT, BATTERY SERVICE TK-90/G
4
F, H, D
ANALYZER-CHARGER AN/USM-432 (NOTE 2)
5
O, F, H, D
6
F, H, D
CABLE ASSEMBLY, POWER ELECTRICAL
CX-11934/U, NO. 4 AWG(NOTE 3)
7
F, H, D
CABLE ASSEMBLY, POWER ELECTRICAL
CX-11779/U, NO. 2/0 AWG (NOTE 3)
8
F, H, D
CHARGER, BATTERY PP-1451/G
9
F, H, D
CHARGER, BATTERY PP-1659/G
10
F
6115-00-475-0029
ENGINE 3KW, 28V DC, MIL-G52428(NOTE 4)
11
F, H, D
POWER SUPPLY PP-1104C/G (NOTE 5)
12
F, H, D
RELAY, REVERSE CURRENT CUTOFF (NOTE 5)
NOTES
1.
DEEP-CYCLE THE BATTERY EVERY 90 DAYS (3 MONTHS). THE QUARTLERY DEEP CYCLE TEST IS
PERFORMED AT DIRECT SUPPORT MAINTENANCE.
2.
ANALYZER-CHARGER AN/USM-432 IS USED TO CHARGE AND ANALYZE BB-693A/U STORAGE
BATTERIES. CHRISTIE RF80GT, AN/GSM-261 OR EQUIVALENT MAY BE USED IF AVAILABLE.
3.
CABLE ASSEMBLIES, POWER, ELECTRICAL CX-11779/U AND CX-11934/U ARE REQUIRED FOR
CHARGING BB-693A/U STORAGE BATTERIES EQUIPPED WITH RECEPTACLE MIL-C-18148A(ASG).
CX-11934/U CAN BE USED UP TO 100 AMPERES DC.
4.
GENERATOR SET, GASOLINE ENGINE IS USED FOR CHARGING WHERE 115- 230-VOLT AC POWER
IS NOT AVAILABLE.
5.
REVERSE RELAY MUST BE CONNECTED TO THE OUTPUT OF POWER SUPPLY PP-1104C/G TO
PREVENT BATTERY FROM DISCHARGING THROUGH THE POWER SUPPLY IN THE EVENT OF
POWER FAILURE.
6.
MULTIMETER AN/USM-223 MAY BE SUBSTITUTED FOR TS-352B/U WHERE 5 PERCENT ACCURANCY
IS REQUIRED.
7.
BALLANTINE DIGITAL VOLTMETER MODEL 3028A MAY BE SUBSTITUTED FOR AN/USM-451 WHERE 1
PERCENT OR BETTER ACCURACY IS REQUIRED.
D-4