TB 9-2320-280-35-11
Section XXX. NTDR POWER AND UHF CABLE INSTALLATION
30-1. Install grommet material (14) in two holes (5) and (15) of left wheelwell (4).
30-2. Route cable (1) from connection box (2) down tool box (3) into rear hole (15) of left wheelwell (4).
30-3. Route cable (1) along underside of left wheelwell (4).
30-4. Route cable (1) through front hole (5) of left wheelwell (4).
30-5. Route cable (1) down front of wheelwell (4) to C-beam (13). Secure cable to wheelwell (4) with
clamps (6) and self-tapping screws (7).
30-6. Route cable (1) along C-beam (13) and secure with clamp (6), capscrew (12), lockwasher (8), and
nut (9).
30-7. Route cable (1) up through hole (10) in frame (11) of multi-net rack (17).
30-8. Route cable (1) through lower hole (16) of multi-net rack (17) and to vicinity of NTDR mounting
bracket (19).
30-9. Route NTDR power cable (18) from battery box to rear of multi-net rack (17).
30-10. Route NTDR power cable (18) along rear of multi-net rack (17) to vicinity of NTDR mounting
bracket (19).
3
1
2
4
~
14
15
5
1
14
6
7
11
6
12
13
10
7
~
~
6
8
9
1.
UHF CABLE 8174914-7 QTY. 1
6.
LOOP CLAMP MS21333-77 QTY. 2
7.
SELF-TAPPING SCREW 9421073 QTY. 2
8.
LOCKWASHER MS35338-43 QTY. 1
9.
NUT, PLAIN ASSEMBLED 9422771 QTY. 1
12.
SCREW MS35206-265 QTY. 1
14.
GROMMET MATERIAL MS35489-7 QTY. 1
Figure 5-81.