TB 9-2320-280-35-12
Section XVI. EPLRS DUAL MOUNT INSTALLATION
16-1. Insert two screws (14) and lockwashers (13) in
holes (12).
16-2. Using EPLRS rack spacer (9) as template, locate, mark, and drill two 0.3125-in. diameter holes (11)
in top shelf of multi-net rack (10).
16-3. Enlarge two holes (11) in EPLRS rack spacer (9) to 0.3125-in. diameter.
16-4. Using EPLRS rack spacer (9) as template, locate, mark, and drill two 0.3125-in. diameter holes (15)
in EPLRS dual mount lower half (8).
16-5. Enlarge four holes (3) in EPLRS dual mount upper half (2) to 0.3125-in. diameter.
16-6. Attach EPLRS mount (1), rack spacer plate (9), and EPLRS dual mount lower half (8) to multi-net
rack (10) with four screws (14), washers (16), lockwashers (13), and nuts (17).
16-7. Attach EPLRS dual mount upper half (2) to EPLRS dual mount lower half (8) with six screws (7),
six lockwashers (5), twelve washers (4), and six nuts (6).
16-8. Attach EPLRS mount (1) to EPLRS dual mount upper half (2) with four screws (14), washers (16),
lockwashers (13), and nuts (17).
1
3
2
2
4
1
6
17
5
~
16
15
4
7
4
7
8
9
11
10
12
~
~
11
~
10
9
13
14
1.
MOUNT, RESILIENT MT- 6146/VSQ-1 QTY. 2
8.
LOWER BASE A3265624 QTY. 1
2.
UPPER BASE A3265626 QTY. 1
9.
SPACER PLATE A3265625 QTY. 1
4.
WASHER MS27183-10 QTY. 12
13.
WASHER MS27183-12 QTY. 8
5.
LOCKWASHER MS35338-44 QTY. 6
14.
SCREW MS90725-36 QTY. 8
6.
NUT MS51967-2 QTY. 6
15.
LOCKWASHER MS35338-45 QTY. 8
7.
SCREW MS90725-8 QTY. 6
16.
NUT MS51967-5 QTY. 8
Figure 5-40.