Figure 5-4. Discharging battery, Storage BB-422/U, Using Discharge Fixture
c.
After discharge (b above), charge the battery as follows:
(1) Charge the battery, using constant-potential or constant-current method. Refer to table 5-1 to
determine the charging voltage for the constant-potential method. Refer to table 5-2 to determine the charging
current for the constant-current method.
(2) After charging the battery, allow it to rest (para
5-7