CHAPTER 2. BATTERY CHARGING INSTRUCTIONS
Figure 1. Pulse Tech Pro-HD.

Frecharging Procedures For Automotive Valve Regulated Lead-Acid Batteries Page Navigation
  3    4    5    6    7  8  9    10    11    12    13  
img
.
TB 9-6140-252-13
0004
BATTERY CHARGING AND TEST EQUIPMENT
INITIAL SETUP:
Not Applicable
GENERAL
Any charger that has a constant voltage output (rated at 12 VDC or 12/24 VDC) that can apply a charge to one or
more batteries at a time using either alligator clamps or NATO slave connector may be used.
To verify the voltage rating of a charger, attach charger to a fully charged battery (6TMF or VRLA), apply power,
wait a couple minutes until the amp meter registers 1 amp or less, then measure the voltage on the leads at the
battery terminals. Do not exceed 15 VDC if charging one 12 volt battery or 30 VDC if charging a 24 volt battery
system.
Constant current chargers are not recommended for charging Valve Regulated Lead-Acid (VRLA) Absorbed Glass
Mat (AGM) batteries, especially to ensure a complete charge of new batteries.
0004-1
03/15/2011Rel(1.8)root(opusualwp)wpno(O00002)


Privacy Statement