TB 9-6140-252-13
0004
BATTERY CHARGERS - Continued
Associated Model PP-1660-F/U (Roll Around) NSN 6130-01-518-7866.
Approximately 2.4 VDC
Minimum Battery Voltage (OCV) Start:
Diagnostic Time:
45-50 minutes
12/24 Capability:
12 and 24 VDC manual select
Charge Time:
24 hours or more
Number of Charge Cycles to Recharge a Battery:
Multiple cycles may be needed
End of Charge Charger Status:
Display givesa statusreading, then beepsevery minute
till power is terminated
Charger has a 45-50 minute diagnostic cycle and will give a defective battery reading. Allow the battery to rest up
to ve minutes and restart. It was found that many batteries required ve or more of these diagnostic cycles before
they begin to take a charge. Once battery started to accept a charge it often would recharge in less than two hours.
This charger comes with a NATO slave connector, interchangeable with the alligator clamp leads.
Model PP-1660-F/U.
03/15/2011Rel(1.8)root(opusualwp)wpno(O00002)