TM 11-6130-392-34
(1) If meter reading is 20 ohms or less; go to
step k.
step s.
(2) If meter reading is less than 7.0 volts; dis-
(2) If meter reading is greater than 20 ohms;
continue testing, send battery charger to next high-
er maintenance level.
k. Remove positive lead of multimeter from A12
(1) If meter reading is 20 ohms or less, go to
pin 41 and connect it to A12 pin 34.
step t.
(1) If meter reading is 7.0 volts or more; go to
(2) If meter reading is greater than 20 ohms,
step l.
(2) If meter reading is less than 7.0 volts; dis-
Go to section V.
continue testing, send battery charger to next high-
t. Insert A6 into its original location. Remove A7
er maintenance level.
l. Press START TIME switch. Check multimeter
(1) If meter reading is 20 ohms or less, go to
while switch is pressed.
step u.
(1) If meter reading is 0 . 1 volt or less; set
(2) If meter reading is greater than 20 ohms,
POWER switch to OFF, and replace A12 (Section
Go to section V.
(2) If meter reading is more than 0 . 1 volt; dis-
u. Insert A7 into its original location. Remove A8
continue testing, send battery charger to next high-
er maintenance level.
(1) If meter reading is 20 ohms or less, go to
step v.
3-2) on the
extender board.
(2) If meter reading is greater than 20 ohms,
n. Set multimeter to 10 VDC scale. Connect nega-
tive multimeter lead to negative () lead of C1 (fig.
Go to section V.
3-3). Connect positive lead (+) to A11 by using pin
v. Insert A8 into its original location. Remove A9
20 on extender board.
(1) If meter reading is between 9.0 and 10.0
volts; go to step o.
(1) If meter reading is 20 ohms or less, go to
step w .
(2) If meter reading is not between 9.0 and 10.0
(2) If meter reading is greater than 20 ohms,
volts; set POWER switch OFF, and replace A11
Go to section V.
o. Set POWER switch OFF. Remove positive lead
w. Insert A9 into its original location. Remove
of multimeter from A11 pin 20 and set multimeter to
the Rx1 scale. Connect positive lead to A11 pin 14 on
(1) If meter reading is 20 ohms or less, go to
extender board.
step x.
(1) If meter reading is 20 ohms or less; go to
(2) If meter reading is greater than 20 ohms,
step p.
(2) If meter reading is greater than 20 ohms; go
Go to section V.
to step r.
x. Insert A10 into its original location. Remove
p. Remove A12 and check multimeter.
(1) If meter reading is 20 ohms or less, go to
remove A11. Connect multimeter leads to pins 12
step q.
and 18 of the A11 board.
(2) If meter reading is greater than 20 ohms;
(1) If meter reading is 20 ohms or less; replace
Go to section V.
q. Insert A12 into its original position. Remove
section V.
(2) If meter reading is greater than 20 ohms;
both leads of multimeter from battery charger and
d i s c o n t i n u e testing, send battery charger to the
remove A11. Connect leads of multimeter to pins 13
next higher maintenance level.
and 14 of A11 and check multimeter.
Test 7. Charging Circuit Printed Wiring Assem-
(1) If meter reading is 20 ohms or less, replace
blies (A6-10) Test.
a. For channels that could not be adjusted for a
section V.
meter reading of 50 mA; determine if there was a
(2) If meter reading is greater than 20 ohms;
discontinue testing, send battery charger to next
(or some lesser) reading.
(1) If no reading at all, on questionable chan-
higher maintenance level.
nel(s), go to step f.
r. Remove positive lead from A11 pin 14 and con-
(2) If there was a meter reading, on question-
nect it to A11 pin 18.
3-13