TM 11-6130-392-34
Figure 4-2. Pin and Terminal Locations for Components Replaced at General Support Level (Sheet 2 of 4)
sure S6 is actuated (in down and closed position)
0.04-0.08 inch coating of red staking compound
when measurements are made.
(SM-A-852314) on S1 and on T1 terminals 1 through
5. Go to section V.
(1) If continuity is good; go to step f.
red staking compound (SM-A-852314) on T1 termi-
f. Peel or pick away red staking compound on
nals 1 through 5. Go to section V.
CB1 (fig. 4-1 and 4-2). Check for continuity between
e. Peel or pick away red staking compound on S6
CB1-2 and CB1-1, and between CB1-4 and CB1-3.
(fig. 4-2 and FO-1). Check for continuity between
Make sure POWER switch is in ON position for this
S6A-C to S6A-NO and between S6B-C and S6B-NO
measurement.
(only two wires each side of interlock switch). Make
(1) If continuity is good; go to step g.
4-9